Mobile/whatsapp: +86-13333858191 Email: [email protected]
Noise detector is designed mainly in accordance with the national standard GB/T 3785.1-2010 "Electroacoustic Sound Level Meter Part 1: Specifications" and the international standard IEC 61672-1:2002 for Class 2 Class X sound level meters. It is mainly used for real-time measurement of various types of noise such as environmental noise, traffic noise, workplace noise, construction noise and social life noise. With this module, customers no longer need to worry about complex noise signal processing, they can focus on their areas of expertise and create value for customers more quickly.
Working voltage |
10~28V |
Power consumption |
27.8mA@24V |
Transmitter circuit working temperature |
-20℃~+60℃, 0%RH~80%RH |
Output signal |
RS485 ModBus-RTU communication protocol |
UART or RS-485 communication parameters |
9600 N 8 1 |
Measuring range |
50dB~120dB |
Frequency weighting |
A weighting |
Frequency response range |
20Hz~12.5kHz |
Response time Fast |
mode: 500ms; Slow mode: 1.5S |
Stability |
Less than 2% in the life cycle |
Reference calibration point |
94dB and 114dB calibration, reference sound pressure 20uPa, frequency 1kHZ |
Noise accuracy |
±0.5dB (at reference pitch, 94dB@1kHz) |
Dust cover influence |
The influence in the range of 50~115db is less than or equal to 0.5dB; the influence in other ranges in the range is less than or equal to 0.7dB |
working environment |
Air temperature:-40~+60℃ |
Relative humidity |
25%~90% |
Static pressure |
65kPa~106kPa |
If you need our products please write down any questions, we will reply as soon as possible.