on-line fixed O2 sensor-TCB4

    • Firm appearance
    • Easy installation and long life
    • Sensor protection function
    • Can be used with DCS, PLC and other systems
    • Built-in passive contact switch output
    • Can be equipped with sound and light warning lights
    • Low maintenance cost

     Mobile/whatsapp:  +86-13333858191     Email:  [email protected]

     

Product description
The point type oxygen O2 detector is applicable to the concentration of oxygen in the ambient air detection, are widely used in metallurgy, power plant, chemical, mine, tunnel,underground pipelines and other places, effective prevention of hypoxia and oxygen poisoning. It is a new type of gas leak detection instrument produced by our company. Its outstanding feature is the use of high-performance imported catalytic combustion, electrochemical, infrared dual-beam gas sensors, combined with sophisticated SMD technology, and it has a good It has the advantages of repeatability and resistance to humidity and temperature interference, long service life, and convenient operation. It is suitable for gas leakage concentration detection in various industrial environments.

TCB4 series point-type gas detectors can convert the leakage gas concentration signal in the air into electrical signals and output remote transmission. It adopts two/three-wire system, 485 bus, switch value and other signal structures. The monitoring instrument or controller host is kept away from the scene to view the detection results .

 

Gas

Measuring range

Optional range

Resolution

Response time

 EX

0-100%LEL

0-100%VOL (infrared)

1%LEL/1%VOL

≤15second

 O2

0-30%VOL

0-30%、0-100%VOL

0.1%/0.01%VOL

≤15second

H2S

0-100PPM

0-50、200、1000PPM

0.1/1PPM

≤15second

CO

0-1000PPM

0-500/2000/5000PPM

0.1/1PPM

≤15second

NO2

0-20PPM

0-50、1000PPM

0.1/1PPM

≤20second

Natural gas

0-100%LEL

0-100%VOL

1%LEL/1%VOL

≤15second

NOX

0-20PPM

0-50、1000PPM

0.1/1PPM

≤20second

CH4

0-100%LEL

0-100%VOL

1%LEL/1%VOL

≤15second

 CO2

0-5000PPM

0-1%、5%、10%VOL (infrared)

1PPM/0.01%VOL

≤20second

NO

0-250PPM

0-500、1000PPM

1PPM

≤20second

N2

0-100%VOL

0-100%VOL

0.1%VOL

≤15second

Alcohol

0-100%LEL

0-100%LEL

1%LEL/1%VOL

≤15second

SO2

0-20PPM

0-50、1000PPM

0.1/1PPM

≤20second

CL2

0-20PPM

0-10、50、100PPM

0.1PPM

≤20second

dichlorosilane

0-20PPM

0-20、100PPM

1/0.1PPM

≤20second

NH3

0-100PPM

0-50、500、1000PPM

0.1/1PPM

≤20second

Silicon tetrachloride

0-20PPM

0-20、100PPM

1/0.1PPM

≤20second

H2

0-1000PPM

0-40000PPM

1/10PPM

≤20second

PH3

0-20PPM

0-20、1000PPM

0.1/1PPM

≤20second

 HCL

0-20PPM

0-20、50、100PPM

0.1/1PPM

≤20second

Acrylonitrile

0-100PPM

0-100PPM

1PPM

≤20second

TVOC

0-100PPM

0-100PPM

1PPM

≤20second

CLO2

0-50PPM

0-10、100PPM

0.1PPM

≤20second

HCN

0-50PPM

0-100PPM

0.1PPM

≤20second

 ETO

0-10PPM

0-100、1000PPM

1PPM

≤20second

 O3

0-10PPM

0-20、100PPM

0.01/0.1PPM

≤20second

 CH2O

0-20PPM

0-50、100PPM

0.1/1PPM

≤20second

 F2

0-10PPM

0-1、10PPM

1/0.1PPM

≤20second

 HF

0-10PPM

0-1、10、50、100PPM

0.01/0.1PPM

≤20second

Xylene, toluene

0-20PPM

50、100PPM

0.1/1PPM

≤20second

Stench

0-100PPM

0-100PPM

1PPM

≤20second

For unlisted gas, please contact our sales department

 

Main function
  • Firm appearance
  • Easy installation and long life
  • Sensor protection function
  • Can be used with DCS, PLC and other systems
  • Built-in passive contact switch output
  • Can be equipped with sound and light warning lights
  • Low maintenance cost
Technical index

Detection principle

electrochemical

Detection of gas

oxygen

Sampling mode

natural diffusion  

Detection range

(0~30%)vol

Resolving

0.1%vol

Measurement error

±3%

Status indication

LCD,LED

Ambient temperature

40°C~70°C (flammable); -20°C~50°C (toxic) Relative humidity: ≤95%RH

Power consumption

3W/way

Response time

T90<20s (flammable); T90<60s (toxic)

Power supply

DC24V/DC36V (two bus)

Use cable

2.5mm²×2(two-wire system); 1.5mm²×3(three-wire system);    1.5mm²×4(four-wire system)

Relay capacity

two groups of switch output

Environmental pressure

(86~106)KPa

Transmission distance

≤1500m

 Explosion-proof type

flameproof

 Explosion-proof certificate number

CNEX18.0305X

Explosion-proof mark

Ex d IIC T6 Gb

Measurement number

2018C239-41

Instrument size:

 131mmX150mmX109mm